The optional APPM is a modified battery pack that shuts down the output of the X26P CEW after 5 seconds and also contains a built-in speaker that alerts you to the impending shut down.
Under stressful situations, audio exclusion might prevent you from hearing the alert from the APPM.
The APPM provides an audible beeping alert for the last two seconds of a trigger-initiated cycle before automatically shutting down the cycle. After a 5-second deployment duration, the energy burst will stop even if your finger is still pulling the trigger switch. The audible beeping alert will continue to
sound until the trigger switch is released. To re-energize the deployed cartridge, first ensure that your finger is off the trigger switch, and then press the trigger again.
Replacing the APPM with a Different Battery Pack
Your CEW will recognize the APPM as a unique type of battery pack. If you remove the APPM and replace it with a different type of battery pack, the X26P CEW will return to its normal configuration. That is, there will no longer be an audio alert, and the energy cycle will continue after five seconds if your finger is still holding down the trigger switch. Always confirm that the CEW performs as expected before returning it to duty after changing any battery pack.
Remove the cartridge before testing the CEW function. See the Unloading section in this manual for more information.