The operator can select four modes of illumination when using the X26 ECD.
LF LASER and Flashlight both illuminate
LO LASER only will illuminate
OF Only Flashlight will illuminate
OO Neither the LASER nor the Flashlight will illuminate and the CID display is dimmed
To change the illumination setting:
- Place the safety switch in the down (SAFE) position, remove the TASER cartridge, and aim the X26 ECD in a safe direction (such as toward the ground). NOTE: The illumination selector is disabled if the safety switch is in the up (ARMED) position.
- Press and hold the Illumination Selector for approximately 1 second until the CID display illuminates.
- Press and release the Illumination Selector to toggle through the four available settings until the setting you desire is designated on the CID. Stop when the setting you desire is displayed.
- The selected mode displays for 5 seconds, and will be the default mode the next time the safety switch is moved to the up (ARMED) position.
Note: Using pens or paper clips to press the Illumination Selector may damage it. Only use your finger to press the Illumination Selector.